List of Commercial Laboratories Suitable for Testing Military Devices



This is a list of commercial laboratories, which have a DLA Weapons Support-VQ letter of suitability to test to the military specifications indicated. Only commercial laboratories that have been issued laboratory suitability for a particular test method are eligible to test the federal stock class type of device called out in a laboratory suitability letter.

This list is divided into three sections; each section is dedicated to particular test standards and methods for which the laboratory has been given suitability.

The first column labeled  Laboratory  gives the name, address, phone number, and point of contact for each laboratory. The second column  Test Methods (Conditions)  lists the test standard (if more than one is included in a section), followed by a colon then the listing of methods from that particular test standard. If only certain conditions of a method are approved, they will be shown in parenthesis following the test condition (eg: 883: 1015, 1014, (A,B,E), 2003). These may include test methods such as those described in ASTM, IPC documents. The third column  Specification  lists the military specifications for QPL/QML electronic and construction components that the laboratory reports having tested. The last column  OPI  lists the DLA Land and Maritime Office of Primary Interest, which is the point of contact for any questions concerning that laboratory.

QPL/QML manufacturers using any of the facilities listed shall perform their own self audit of the commercial laboratory, initially and annually thereafter to verify continual compliance with the military requirements.

Laboratory suitability granted by DLA Weapons Support-VQ prohibits commercial laboratories from removing or altering the military specification marking required on the device. A device that fails testing conditions shall be identified (isolated) as a reject and returned to the manufacturer for verification of failure mode.

These commercial laboratories are subject to the conditions as stated in DoD 4120.24M (Defense Standardization and Specification Program, Policies, Procedures and Instructions) and SD-6 (Provisions Governing Qualification) and the December 2020 DLA Weapons Support-VQ Laboratory Suitability Information booklet.

This list will be revised periodically, but it is recommended that for current laboratory status, or to clarify any questions pertaining to the use of this list, the following individuals be contacted:

OfficeNameTelephoneDSNEmailComments
VQC Jerrod Abel 614-693-7604 850-7604 vqc.ja@dla.mil MIL-PRF-38535, MIL-STD-883, QTSL
VQC Jonathan Puhalsky 614-693-9331 850-9331 vqc.jp@dla.mil QTSL
VQC Kam Shing Yu 614-693-0176 850-0176 vqc.ksy@dla.mil MIL-PRF-38535, MIL-STD-883, MIL-STD-202 (FSC5925)
VQE Sterling Henarie 614-693-2401 850-2401 vqe.sh@dla.mil MIL-STD-750
VQE Courtney Hernandez Paz 614-693-0672 850-0672 vqe.chp@dla.mil MIL-PRF-31032, MIL-PRF-55110, MIL-PRF-50884
VQE Yinhe Wang 614-693-2499 850-2499 vqe.yw@dla.mil MIL-PRF-31032, MIL-PRF-55110, MIL-PRF-50884, MIL-STD-202
VQH Sema Kazemi 614-693-0519 850-0519 vqh.sk@dla.mil MIL-PRF-38534, MIL-STD-883

Standard(s)


StandardDescription
MIL-STD-1344 Test Methods for Electrical Connectors (was cancelled on October 22, 2004, and replaced by EIA364)
MIL-STD-167-1 Mechanical Vibrations of Shipboard Equipmnt (Type I - Environmental and Type II - Internal)
MIL-STD-202 Test Methods for Electronic and Electrical Component Parts
MIL-STD-461 Requirements for the Control of Electromagnetic Interference Characteristics of Subsystems and Equipment
MIL-STD-462 Test Method Standard for Measurement of Electromagnetic Interference Characteristics
MIL-STD-750 Test Methods for Semiconductor Devices
MIL-STD-810 Environmental Test Methods and Engineering Guidelines
MIL-STD-883 Test Methods and Procedures for Microelectronics


Search by STANDARD:     AND/OR by TEST METHOD:            


LaboratoryTest Methods (Conditions)OPI
A. A. Technology, Inc.
101 Trade Zone Drive
Ronkonkoma, NY 11779
United States
Mr. Tony Yang
Phone: (631) 913-0400  
Fax: (631) 913-0401
PWB: Electrical Testing Only, Printed Boards
 VQE  
A2Z Test Lab
220 Power Court
Sanford, FL 32771
United States
Mr. Chris Almendarez
Phone: (407) 323-3390  
Fax: (407) 323-3115
750: 1001 (A, B, C, D), 1021, 1041, 1046, 1051 (A, B, C, F, G), 2006, 2016, 2046, 2056, 2057, 2081, 2082
810: 500 (Low Pressure Altitude), 501 (High Temp), 502 (Low Temp), 503 (Temp Shock), 507 (Humidity), 509 (Salt Fog), 514 (Vibration), 516 (Shock)
202: 101 (Salt Atmosphere), 103 (Humidity), 106 (Moisture Resistance), 107 (Thermal Shock), 201 (Vibration), 204 (Vibration High Frequency), 212 (Acceleration), 213 (Shock), 214 (Random Vibration)
EIA-364: 14
 VQE  VQP
AAA Test Lab, Inc.
2320 Commerce Park Drive
Palm Bay, FL 32905
United States
Mr. Hayden Green
Phone: (877) 369-6547  
883: 1004, 1005 (A-E), 1008 (A-H), 1010 (A-F), 1015 (A-F), 2003 Test A, 2004 B1, 2010 A,B, 2009, 2011 D, 2012, 2013, 2018, 2021, Electrical Test per MIL-STD-883 paragraph 4.5
QTSL: Testing per AS6171 General Requirements and Slash sheets 2 (Methods A-E), 3, 4, 5, and 7 (Limited Electrical Test per QTSL-5961/5962 3.1.3 Troom)
VQC   
Advanced Component Testing
3279 Veterans Hwy, #D8
Ronkonkoma, NY 11779
United States
Mr. Rob Cohen
Phone: (631) 676-6390  
883: 2003 (Test A, B), 2015
QTSL: Testing per AS6171 General Requirements and Slash sheets 2 (Methods A-E), 3, 4, 5, and 7 (Limited Electrical Test per QTSL-5961/5962 3.1.3 Troom)
202: 208, 209, 215, and 303
750: 2066, 3001, 3011, 3026, 3036, 3041, 3061, 3401, 4001, 4011, 4016, 4021, 4022
VQC VQE  
Akron Rubber Development Laboratory, Inc.
2887 Gilchrist Road
Akron, OH 44305
United States
Mr. Tom Brock
Phone: (330) 794-6600  
Fax: (330) 794-6610
Misc: Low Temperature Resistance, Liquid Immersion, and Ozone Resistance
   VQP
Alter Technology TUV Nord S.A.U.
C/ Tomas Alba Edison 4, Sevilla
, 41092
Spain
Mr. Manuel Dominguez
Phone: 34 954437050  
Fax: 34 954437339
750: 1019 (B, C)
 VQE  
American Environments Co.
17 Commercial Blvd.
Medford, NY 11763
United States
Ms. Melissa Larson
Phone: (631) 736-5883  
Fax: (631) 736-5272
810: 500, 501, 502, 503, 507, 508, 509, 510, 514, 516
202: 101, 103, 104, 105, 106, 107, 108, 109, 110, 201, 204, 207, 212, 213, 214, 215, 301, 302
461: CE101, CE102, CS101, CS114, CS116, RE101, RE102, RS101, RS103
   VQP
Anloy Technologies
6307 Lohman Ford Rd. Suite 201
Lago Vista, TX 78645
United States
Mr. Kyle Rodenbeck
Phone: (512) 388-2313  
Fax: (512) 388-2781
750: 3001, 3011, 3026, 3030, 3036, 3061, 3071, 3076, 3401, 3403, 4011, 4016, 4022
883: 1005 (A-D), 1015 (A-D), Electrical Test per MIL-STD-883 paragraph 4.5
VQC VQE  
Astrocom Electronics
115 D. K. Lifgren Dr.
Colliersville, NY 138203682
United States
Mr. Anthony Lorence
Phone: (607) 432-1930  
Fax: (607) 432-1286
202: 101, 104, 105, 106, 107, 108, 210, 301, 302
Misc: SK-N-86.4, ASTM D-1149
810: 414, 500, 501, 502, 503, 507, 509, 512, 514, 520
   VQP
Burrant Chemicals, LLC.
10109 Piper Ln Suite 120
Bristow, VA 20136
United States
Mr. Jeff Burress
Phone: (703) 257-0217  
Fax: (703) 331-5601
PWB: Tensile Strength, Elongation, Copper Purity (as defined in MIL-PRF-31032/1-6)
 VQE  
CAES Environmental Test Services (San Diego)
9404 Chesapeake Dr.
San Diego, CA 921231303
United States
Mr. Gustavo Roman
Phone: (858) 302-1171  
Fax: (858) 522-5968
883: 1011 (A-C), 2002 (A-D), 2003, 2004 (B2), 2007 (A-C), 2020 (A, B), 2026 (A-K)
202: 204, 213
  VQH 
Contech Research
750 Narragansett Park Drive
Rumford, RI 02916-1035
United States
Mr. George Masganas
Phone: (401) 865-6440  
Fax: (401) 383-0336
EIA-364: 2, 3, 5, 6, 7, 8, 9, 10, 11, 13, 17, 20, 21, 23, 24, 25, 26, 27, 28, 29, 30, 31, 32, 35, 37, 38, 40, 41, 42, 46, 52, 53, 54, 71, 83, 99, 104, 105, 106
202: 101, 103, 104, 105, 106, 107, 108, 111, 112, 201, 204, 208, 210, 211, 213, 214, 215, 301, 302, 303, 304, 305, 307, 310, 311, 312
Misc: 12883 (except Static Load and Porosity) 22992 Cable Pull Out, Contact Engagement and SeparationForce, Drop Test, Heat Rise, Tensile, Water Immersion, Abrasion, and Shell-to-Contact Resistance Grounding
   VQP
Criteria Labs
706 Brentwood Street
Austin, TX 78744
United States
Ms. Yolanda Guillory
Phone: (512) 637-4516  
Fax: (512) 637-4750
883: 1005 (A-E), 1009 (A-D), 1010 (A-C), 1014 (A1, A2, C1), 1015 (A-E), 2001 (A-E), 2009, 2010, 2011, 2015, 2016, 2018, 2019, 2020A, 2027
VQC   
DLS Electronics Systems, Inc.
1250 Peterson Drive
Wheeling, IL 60090
United States
Mr. Brian Mattson
Phone: (847) 537-6400  
83528: Electro-Magnetic Pulse and Shielding Effectiveness; Electrical Stability during Vibration (section 4.5.13); Fluid Immersion (section 4.5.17)
  VQH 
DNB Engineering Inc.
1750 Raymer Avenue
Fullerton, CA 92833
United States
Mr. Michael Neis
Phone: (714) 870-7781  
Fax: (714) 870-7781
364: Acceleration (01), Air Leakage (02), Altitude Immersion (03), Contact Insertion and Removal Force (05), Contact Resistance (06), Contact Axial Concentricity (07), Crimp Tensile Strength (08), Durability (09), Fluid Immersion (10), Resistance to Solvents (11), Mating and Unmating Forces (13), Temp Life (17), DWV (20), IR (21), Simulated Life (22), Low Signal Level Contact Resistance (23), Maintenance Aging (24), Salt Spray (26), Shock- specified pulse (27), Vibration (28), Contact Retention (29), Capacitance (30), Humidity (31), Thermal Shock (32), Insert Retention (35), Contact Engagement and Separation Force (37), Cable pull-out (38), Impact (42), Corona (44), Microsecond Discontinuity (46), Magnetic Permeability (54), EMI Shielding Effectiveness (66), Solder Wicking (71), Lightning Strike (75), Shell to Shell Resistance (83), Dust (91), Altitude-Low Temp (105), Standing Wave Ratio (106)
461: CE101, CE102, CS101, CS114, CS115, CS116, RE101, RE102, RS101, RS103
202: Salt Atmosphere (corrosion) (101), Immersion (104), Barometric Pressure (reduced) (105), Moisture Resistance (106), Thermal Shock (107), Life (at elevated ambient temp) (108), Seal (112), Vibration (201), Vibration, high frequency (204), Solderability (208), Resistance to Solder Heat (210), Terminal Strength (211), Shock (specified pulse) (213), Random Vibration (214), Resistance to Solvents (215), DWV (301), IR (302), DC Resistance (303)
83538: Lightning Strike, Shell to Shell Conductivity
85045: Electromagnetic Effects
38999: Resistance to Indirect Lightning Strike, Shell to Shell Conductivity, EMI Shielding
83528: Electrical Stability During Vibration, EMP Survivability, Shielding Effectiveness
   VQP
DPA Components International
2251 Ward Ave
Simi Valley, CA 93065-7556
United States
Mr. Douglas J Schweitzer
Phone: (805) 581-9200  
Fax: (805) 581-9790
QTSL: FSC 5962 Limited Electrical Test per QTSL-5961/5962 3.1.3
750: 1016, 1020, 1021, 1022, 1026, 1031, 1037, 1038 (A, B), 1039 (A, B), 1041, 1042 (A, B, C, D), 1051 (A, B, C, F, G), 1056 (A, B, C, D), 2006, 2016, 2026, 2052 (A), 2066, 2071, 2076, 2077, 2081, 2082, 2100, 2101, 2102, 3001, 3011, 3026, 3030, 3036, 3041, 3061, 3066, 3076, 3240, 3246, 3431, 3453, 3474, 4001, 4011, 4016, 4021, 4022, 4023, 4136, 4206, 4211
883: 1003 (A-F), 1004, 1005 (A-E), 1008 (A-F), 1009 (A), 1010 (A-C), 1011 (A-C), 1014 (A1, A2 (Excludes Class K testing of hybrid devices), C1). 1015 (A-E), 2001 (A-E, (Y1)), 2002 (A-D), 2003 (Test A), 2004 (A-E), 2007 (A), 2009, 2010 (A,B), 2011 (D,F), 2012, 2013, 2014, 2015, 2016, 2018, 2019, 2020 (A, B), 2021, 2023, 2024, 2025, 2027, 2028, 2030, 2036 (A-D, I-K), 2037, 3015, 3023, JESD22-A110, JESD22-A118, Electrical Test per MIL-STD-883 paragraph 4.5
VQC VQE  
Dayton T. Brown, Inc.
1175 Church Street
Bohemia, NY 117165031
United States
Ms. Mary Alice Der Aris
Phone: (631) 589-6300  
202: 101, 106, 107, 110, 201, 204, 213
EIA-364: 17, 26, 27, 28, 31, 32, 105
   VQP
ECR Laboratories, Inc.
490 Mayock Rd
Gilroy, CA 95020
United States
Mr. Gregorio La Rosa
Phone: (408) 676-9317  
883: 2011 (C-D), 2012, 2018, 2019, 2020 (A-B)
VQC   
EMS Analytical Labs
2735 Saturn Street
Brea, CA 92821
United States
Mr. James Economus
Phone: (714) 646-9711  
Fax: (714) 646-9745
PWB: Tensile Strength, Elongation, Copper Purity (as defined in MIL-PRF-31032/1-6)
 VQE  
Element Materials Technology
3200 S 166th St
New Berlin, WI 53151
United States
Ms. Denise Besting
Phone: (262) 782-6344   Extension: 30524
Fax: (262) 782-3653
Misc: Universal Joints (FSC 3010): (as defined in MIL-DTL-6193) End and Side Play, Axial Load, Tightness, Static Torque Load, Torsional Play, Endurance Test, Visual and Dimensional Inspection
 VQE  
Element Materials Technology Anaheim
1435 S. Allec St.
Anaheim, CA 92805
United States
Mr. Russell Shepherd
Phone: (714) 999-1616  
PWB: Full Suitability
Misc: ASTM D 635, ASTM D 1005, ASTM E 345
Conformal Coating: Full Suitability (MIL-I-46058)
202: 107, 215, 301, 302
 VQE  
Element Materials Technology Baltimore
5 North Park Dr.
Hunt Valley, MD 21030
United States
Ms. Sarah Brammer
Phone: (410) 584-9099  
810: 508
Misc: ASTM D 150, ASTM D 635, ASTM D 1005, ASTM G 21, ASTM E 345
1344: 1002, 1003, 1005, 1012, 1015, 2003, 2007, 2010, 2012, 2013, 2014, 2016, 2017, 3001, 3002, 3003, 3004, 3007
PWB: Full Suitability
Conformal Coating: Full suitability (MIL-I-46058)
883: 5011 (Materials, Viscosity, Pot Life, Shelf Life, Thermogravimetric Analysis, Ionic Impurities, Bond Strength (Lapshear), Thermal Conductivity, Volume Resistivity, Dielectric Constant, Dissipation Factor, Coefficient of Linear Thermal Expansion)
202: 103, 104, 106, 107, 111, 208, 210, 211, 215, 301, 302, 305, 307
 VQE VQH VQP
Elite Electronic Engineering
1516 Centre Cir.
Downers Grove, IL 605151019
United States
Mr. Kevin Halpin
Phone: (630) 495-9770  
Fax: (630) 495-9785
EIA-364: 03, 06, 10, 17, 21, 22, 23, 26, 27, 28, 31, 32, 105
461: CE101, CE102, CS101, RE101
202: 101, 103, 104, 105, 106, 107, 108, 109, 110, 201, 204, 211, 212, 213, 214, 215, 301, 302, 303, 304, 307, 310
   VQP
Engineering and Solutions Technology (EAST)
951 George Street
Santa Clara, CA 95054
United States
Mr. Tom Klawitter
Phone: (408) 320-2690  
883: 1004, 1005 (A-D), 1006, 1010 (A-F), 1011 (A-C), 1014 (A2, C1), 1015 (A-D), 2001 (D-E), 2002 (B), 2003 (Test A), 2004 (B1, B2, D), 2007 (A), 2009, 2011 (D), 2015, 2016, 2024, 2025, 3015, Electrical Test per MIL-STD-883 paragraph 4.5
VQC   
Environment Associates Inc.
2300 Cape Cod Way
Santa Ana, CA 927033562
United States
Mr. Steve Hollinger
Phone: (818) 709-0568   Extension: 232
83538 Test Par.: 4.6.4.2, 4.6.4.3, 4.6.4.4, 4.6.11, 4.6.28, 4.6.31, 4.6.32.1, 4.6.36, 4.6.37,
810: 509
EIA-364: 03, 05, 06, 07, 08, 09, 10, 13, 17, 20, 21, 23, 24, 25, 26, 27, 28, 29, 31, 32, 35, 38, 54, 83, 105
202: 101, 103, 104, 105, 106, 107, 108, 201, 204, 208, 210, 211, 213, 215, 301, 302, 303 305, 307
883: 1009
   VQP
Environment Associates Inc.
9604 Variel Ave.
Chatsworth, CA 913114913
United States
Mr. Steve Hollinger
Phone: (818) 709-0568   Extension: 232
Fax: 818-709-8914
883: 1009
810: 509
EIA-364: 03, 20, 21, 27, 31, 32, 105
202: 101, 103, 105, 106, 110, 204, 213, 214
   VQP
Epoxy Technonology Inc.
14 Fortune Dr.
Billerica, MA 018213922
United States
Ms. Donna Sullivan
Phone: (978) 667-3805  
Fax: (978) 667-8693
883: 5011 (for in-house use only): Materials, Viscosity, Pot Life, Shelf Life, Thermogravimetric Analysis, Ionic Impurities, Bond Strength, Volume Resistivity, Dielectric Constant, Dissipation Factor, Coefficient of Linear Thermal Expansion, Thermal Conductivity
  VQH 
Eurofins EAG Engineering Science, LLC
2710 Walsh Ave.
Santa Clara, CA 95051
United States
Mr. Robert Bruening
Phone: (949) 521-6242  
883: Walsh Ave: 1004, 1005 (A-E), 1006 (A-E), 1008, 1010 (A-C), 1015 (A-E), 3015, 3023 (Class 1 and Class 2), ESDS HBM (JS-001), ESDS CDM (JS-002), HAST Biased (JESD22-A110), HAST Unbiased (JESD22-A118); Kifer Rd: 2030
VQC   
Eurofins EAG Engineering Science, LLC
15 Morgan
Irvine, CA 92618
United States
Mr. Robert Bruening
Phone: (949) 521-6242  
750: 2052 (A), 2076, 2077
883: 1004, 1005 (A-D), 1008 (A-C), 1010 (A-C), 1011 (A-C), 1015 (A-D), 2012, 2020 (A, B), 2030, 3015, 3023, ESDS HBM (JS-001), ESDS CDM (JS-002), HAST Biased (JESD22-A110), HAST Unbiased (JESD22-A118)
VQC VQE  
Eurofins EAG Materials Science, LLC
103 Commerce Blvd
Liverpool, NY 13088
United States
Ms. Frona P Wilson
Phone: (970) 224-0220  
750: 1018 (volume of gas at 1 atm: 0.01cc to 20cc)
883: 1008, 1018 (volume of gas at 1 atm: 0.01cc to 20cc)
VQC VQE  
Eurofins Electrical and Electronic Testing NA, LLC
914 West Patapsco Avenue
Baltimore, MD 21230
United States
Mr. Johnnie Evans
Phone: (410) 949-1929  
Fax: (410) 354-3313
Misc: Life (At Elevated Ambient Temp) per 202 Method 108, Mating Durability per EIA-455-21, and Low Pressure Altitude per 810 method 500
83526: Ambient Light Susceptibility
55181: Air Leakage, Bounce, Contact Resistance, DWV (sea level and high altitude) (364-20), IR (364-21), Vibration (364-28)
85045: Crosstalk, Temp Cycling, Thermal Shock,Temp/Humidity Cycling, Storage Temp, Life Aging, Weathering, Shock
49291: Mechanical Strippability, Macrobend Attenuation, Temp/Humidity Cycling, Temp Cycling, Life Aging, Storage Temp
29504: All Tests Except: Interoperability, Circular Runout
24728: Identification Markings, V and M Inspection, Temp Life, Thermal Shock, Temp Humidity Cycling, Salt Spray, Water Pressure, Fluid Immersion, Vibration, Shock, Operating Temp, Magnetic Permeability
28876: All Tests Except: Interoperability, Shock, Electromagnetics Effects, Ozone Exposure
   VQP
Experior Laboratories
1635 Ives Avenue
Oxnard, CA 93033
United States
Mr. Lorenz Cartellieri
Phone: (805) 483-3400   Extension: 111
Fax: (805) 483-5484
1344: 1001, 1012, 2005, 2009, 2017 and Environment/Mechanical
DoD-1678: 4020, 4030
901: MIL-STD-901, Shock
Misc: Note: The test methods are explained under particular sections of the referenced specifications in the below cases.MIL-DTL-83522 (4.8.10, 4.8.13, 4.7.11.3, 4.7.16, 4.7.6, 4.7.2, 4.7.15, 4.8.6, 4.8.1, 4.8.9, 4.8.2, 4.8.7, 4.8.4, 4.7.11, 4.8.3, 4.7.11.4, 4.8.5)MIL-DTL-38999 (4.5.13.1, 4.5.4, 4.5.2, 4.5.20.1, 4.5.12, 4.5.45, 4.5.8, 4.5.11.1, 4.5.10.1, 4.5.14, 4.5.48, 4.5.25, 4.5.30, 4.5.26, 4.5.7, 4.5.17, 4.5.16, 4.5.15, 4.5.22, 4.5.25.1, 4.5.34, 4.5.3, 4.5.23, 4.5.24, 4.5.27, 4.5.30.1, 4.5.31, 4.5.33, 4.5.34.1, 4.5.38, 4.5.35, 4.5.40, 4.5.19, 4.5.18, 4.5.44, 4.5.46)MIL-DTL-83526 (4.8.3, 4.9.14, 4.9.22, 4.9.23, 4.9.27, 4.9.29, 4.10, 4.9.30, 4.9.26, 4.9.17, 4.9.18, 4.9.19, 4.8.7, 4.9.16, 4.9.11, 4.9.12, 4.8.4, 4.9.6, 4.9.7, 4.9.20, 4.9.15, 4.9.21, 4.9.28, N.B.C. Decontamination)MIL-PRF-28876 (4.6.5.1, 4.6.5.2, 4.6.5.3, 4.6.5.4, 4.6.5.5, 4.6.5.7, 4.6.6.16, 4.6.4.1, 4.6.4.2, 4.6.6.5, 4.6.6.6, 4.6.4.6, 4.6.6.9, 4.6.6.10, 4.6.6.7, 4.6.2.3, 4.6.33, 4.6.4.7, 4.6.4.5, 4.6.6.11, 4.6.6.3, 4.6.6.2, 4.6.5.6)MIL-PRF-29504 (4.8.2, 4.6.6.14, 4.6.6.15, 4.6.6.3, 4.6.6.1, 4.9.12, 4.9.9, 4.9.6, 4.9.8, 4.6.6.10, 4.6.2.1, 4.9.11, 4.8.2, 4.9.12, 4.9.11, 4.6.6.10, 4.9.5, 4.9.14, 4.8.4)MIL-PRF-49291 (4.7.3.5, 4.8.9, 4.8.2, 4.8.3, 4.8.4, 4.7.2.4, 4.8.1, 4.8.8, Splice Compatibility, Coating Adherence (Fiber Pullout Test))MIL-PRF-85045 (4.7.5.16.2, 4.7.4.3, 4.7.6.1, 4.7.6.3, 4.7.6.4, 4.7.6.6, 4.7.5.3, 4.7.6.2, 4.7.5.8, 4.7.6.13, 4.7.5.4, 4.7.5.5, 4.7.5.6, 4.7.5.1, 4.7.5.1.1, 4.7.5.2, 4.7.5.7, 4.7.5.9)
810: 500
202: 101, 108, 204, 213
EIA/TIA: 364-02, 364-06, 364-09, 364-10, 364-14, 364-21, 364-24, 364-26, 364-29, 364-32, 364-35, 364-42, 364-45, 364-54, 364-83
   VQP
GD4 Test Services
5301 Riata Park CtE120-A
Austin, TX 78727
United States
Mr. George Jastroch
Phone: (512) 535-1677  
Fax: (512) 225-1522
QTSL: Testing per AS6171 General Requirements and Slash sheets 2 (Methods A-E), 3, 4, 5, and 7 (Limited Electrical Test per QTSL-5961/5962 3.1.3 Troom)
VQC   
Gardien Services Canada, Inc. (Toronto)
79 Milliken Blvd., Unit 3
Toronto, ON M1V 1V3
Canada
Mr. Rick Meraw
Phone: 4162920726  
PWB: Electrical Testing Only, Printed Boards
 VQE  
Gardien Services USA, Inc. (Anaheim)
1191 N. Red Gum Street
Anaheim, CA 92806
United States
Mr. Todd Kolmodin
Phone: (714) 630-4600  
Fax: (714) 683-2108
PWB: Electrical Testing Only, Printed Boards
 VQE  
Gardien Services USA, Inc. (Loveland)
1513 Taurus Ct.
Loveland, CO 80537
United States
Mr. Steve Riedman
Phone: (303) 527-1200  
PWB: Electrical testing Only, Printed Boards
 VQE  
Gardien Services USA, Inc. (Plymouth)
14000 25th Avenue, Ste. 112
Plymouth, MN 55447
United States
Mr. Tom Elliott
Phone: (503) 357-9184  
Fax: (503) 359-7633
PWB: Electrical Testing Only, Printed Boards
 VQE  
Global ETS, LLC
2631 Success Dr.
Odessa, FL 33556
United States
Mr. Dan Tang
Phone: (727) 807-7991  
QTSL: Testing per AS6171 General Requirements and Slash sheets 2 (Methods A-E), 3, 4, 5, and 7 (Limited Electrical Test per QTSL-5961/5962 3.1.3 Troom)
VQC   
Golden Altos
44061 Old Warm Springs Blvd.
Fremont, CA 94538
United States
Ms. Karla Dy
Phone: (408) 956-1010   Extension: 132
883: 1004, 1005 (A-D), 1008 (A-G), 1009 (A-D), 1010 (A-F), 1011 (A-C), 1014 (A1, A2, C1), 1015 (A-D), 2001 (A-E), 2002 (A-B), 2003 (Test A, B) , 2004 (B1, B2, D), 2007 (A), 2009, 2010 (A, B), 2011 (D), 2014, 2015, 2016, 2019, 2020 (A, B), 2023, 2024, 2025, 2027, 2036, 2037
VQC   
Henkel/Ablestik
20021 Susana Rd.
Rancho Dominguez, CA 902215721
United States
Ms. Kayla Corriher
Phone: (310) 761-4851  
Fax: (310) 537-3914
883: 2019 (for in-house use only), 5011 (for in-house use only): Materials, Viscosity, Pot Life, Shelf Life, Thermogravimetric Analysis, Ionic Impurities, Bond Strength, Thermal Conductivity, Volume Resistivity, Dielectric Constant, Dissipation Factor, Coefficient of Linear Thermal Expansion
  VQH 
Hi-Rel Laboratories
6116 N Freya Street
Spokane, WA 99217
United States
Mr. Cedric Devaney
Phone: (509) 325-5800  
750: 1022, 1071, 2005, 2026, 2036, 2038, 2052, 2066, 2071, 2074, 2076, 2101, 3001, 3036, 3061, 3076, 4011, 4016, 4022
883: 1014 (A1, A2, C1, D), 2003 (Test A), 2009, 2012, 2016, 2018, 2020 (A, B), 2030
VQC VQE  
Honeywell Aerospace, Inc.
13350 US HWY 19 N
Clearwater, FL 33764-7226
United States
Mr. Jacob Groves
Phone: (727) 539-2937  
883: 1019 (A-E and ELDRS), 1020, 1021, 1023
VQC   
IIA Lab Services, LLC
240 E. Caribbean Drive
Sunnyvale, CA 94089
United States
Mr. Frank Sherlock
Phone: (408) 734-4400  
883: 2012 (Film), 2020 (A, B)
VQC   
ISE Labs Inc.
2201 Qume Drive
San Jose, CA 95131
United States
Ms. Saeko Reignierd
Phone: (510) 687-2415  
Fax: (510) 498-8746
883: 1004, 1005 (A-D), 1008 (A-C), 1009 (A, B), 1010(A-C), 1011 (B, C), 1014 (C1), 1015 (A-F), 2001 (A, B, D, E (Y1 orientation only)), 2002 (A, B), 2003 (Test A, B), 2004 (B1, B2, D), 2007 (A), 2009, 2011 (D), 2012, 2013, 2014, 2015, 2016, 2019, 2020 (A, B), 2024, 2025, 2027, 2028, 3015, HAST Unbiased (JESD22-A118)
VQC   
Innovative Circuits Engineering, Inc. (ICE)
2310 Lundy Ave.
San Jose, CA 951311408
United States
Ms. Serena Perez
Phone: (408) 955-9505   Extension: 247
883: 1005 (A-D), 1010 (A, B, C, F), 1015 (A-D), 2012, 2030, 3015, ANSI/ESDA/JEDEC JS-001 (HBM), ANSI/ESDA/JEDEC JS-002 (CDM)
VQC   
Integra Technologies Silicon Valley
1635 McCarthy Blvd
Milpitas, CA 95035
United States
Ms. Nawal Cotran
Phone: (408) 321-6556  
883: 1005 (A-E), 1008 (A-E), 1010 (A-C), 1014 (A2,C1), 1015 (A-E), 2001 (A-E), 2009, 2010 (A, B), 2011 (D), 2019, 2023, 2024, 2027, HAST Biased (JESD22-A110)
VQC   
Integra Technologies, Inc.
3718 Rock Road, Suite 800
Wichita, KS 67266
United States
Mr. Carey Hobbs
Phone: (407) 296-5686  
883: 1005 (A-E), 1010 (A-C), 1014 (A1, A2, C1), 1015 (A-E), 2003 (Test A), 2009, 2010 (A,B), 2011D, 2012, 2015, 2016, 2018, 2019, 2020 (A,B), 2030, Electrical Test per MIL-STD-883 Paragraph 4.5
750: 1016, 1022, 1026, 1027, 1031, 1032, 1036, 1037, 1038 (A, B), 1039 (A, B), 1042 (A, B, C), 1051 (A, B, C, F, G), 1081, 2026, 2031 (B, I, J, K), 2036 (A, E), 2066, 2071, 2100, 3001, 3011, 3026, 3030, 3036, 3041, 3061, 3066, 3071, 3076, 3100, 3131, 3236, 3240, 3261, 3320, 3401, 3403, 3404, 3405, 3407, 3411, 3413, 3415, 3421, 3475, 3501, 3505, 3510, 3570, 3575, 4011, 4016, 4021, 4071, 4076, 4101, 4136, 4206, 4211, 4219, 4221, 4226
VQC VQE  
Intertek
16015 Shady Falls Road
Elmendorf, TX 78112
United States
Mr. Michael Dey
Phone: (210) 635-8127  
85045: Flammability (60-degree angle), Flame extinguishing and smoke generation, Toxicity index, Smoke index, and Flaming Smoke Generation
17: Toxicity, Flame Propagation, and Smoke Index
   VQP
Intertek ETL SEMKO
1717 Arlingate Lane
Columbus, OH 43228
United States
Mr. Michael Lindeman
Phone: (614) 279-8090  
EIA/TIA: Fungus Resistance (455-56) (M85045 and M49291)
   VQP
Intertek Testing Services NA, Inc.
3933 US Route 11
Cortland, NY 13045
United States
Mr. Kenneth Riedl
Phone: (607) 758-6356  
Fax: (607) 758-3683
17: Abrasion Resistance, Weathering, Immersion, Acid Gas Generation, Halogen Content, Cold Bend, Tear Strength (ASTM D470), Physicals (aged), Tensile Strength & Elongation, Durometer Hardness, and Heat Distortion
85045: Weathering, Fluid Immersion, Durability of Identification, Cable Jacket Tear Strength, Cable-to-Cable Abrasion, and Cable Scraping Resistance
85045: 17025 accredited: Acid Gas Generation and Halogen Content: Accreditation to ISO/IEC 17025 for these MIL-PRF-85045 Tests.
   VQP
IsoVac Engineering Incorporated
614 Justin Avenue
Glendale, CA 912012327
United States
Mr. Jimmie Neff
Phone: (818) 552-6200  
Fax: (818) 241-0781
750: 1071 (A, B, G1, G2)
883: 1014 (B1, B2)
 VQE VQH 
Lew Rauch D. SC. Inc.
517 W. Melbourne Road
Springfield, MO 65810
United States
Ms. Stephanie Rauch Hesser
Phone: (417) 866-6161  
202: 208, 210
EIA-364: 02, 03, 05, 06, 10, 13, 20, 21, 24, 25, 26, 27, 28, 29, 31, 32, 37
   VQP
Magnetika/Phillipsburg
300 Red School Ln.
Phillipsburg, NJ 08865
United States
Mr. Tom Raidline
Phone: (908) 454-2600  
Fax: (908) 454-3742
202: 103, 104, 105, 106, 107, 108, 111, 201, 204, 208, 210, 211, 213, 214, 215, 301, 302, 303, 304, 305, 306
   VQP
Mead Testing Ltd.
Unit 25 Mead Industrial Estate River Way, Harlow
Essex, England CM20 2SE
United Kingdom
Dr. C J Jones
Phone: 441279635864  
883: 1008 (C), 1018 (volume of gas at 1 atm: 0.1cc to 10cc)
VQC   
MicroStar Lab
130 Erick Street
Crystal Lake, IL 60014
United States
Ms. Debbie Koester
Phone: (815) 526-0954  
TIA/EIA: 455-56 (Fungus Resistance of Optical Fiber and Cable) and MIL-STD 810 Method 508 (Fungus)
   VQP
Micross Clearwater
4400 140th Ave N Ste 140
Clearwater, FL 33762
United States
Ms. Gabriela Manugas
Phone: (727) 532-1777  
QTSL: Testing per AS6171 General Requirements and Slash sheets 2 (Methods A-E), 3, 4, 5, and 7 (Limited Electrical Test per QTSL-5961/5962 3.1.3 Troom)
750: 3001, 3011, 3036, 3041, 3061, 3066, 3071, 3076, 3405, 3407, 3411, 3413, 4001, 4011, 4016, 4021, 4022, 4023
VQC   
Micross Components Modification Services (CMS)
1050 Perimeter Road
Manchester, NH 03103
United States
Mr. Paul Davis
Phone: (603) 912-4048  
883: 2003
VQC   
Micross Components, Orlando
1810 S. Orange Blossom Trail
Apopka, FL 32703
United States
Mr. Steven White
Phone: (813) 892-1558  
750: 1038 (A, B), 1039 (A, B), 1040 (B), 1042 (A, B), 1051 (C), 2006 (A), 2016, 2069, 2070, 2072, 2073, 2077, 4066 (A, B)
883: 1004, 1005 (A-F), 1008 (A-F), 1009 (A-D), 1010 (A, B, C), 1011 (A-C), 1014 (A1, A2, B1, B2, B2/B1,C1), 1015 (A-F), 2001 (A-E), 2002 (B), 2003 (Test A-C), 2004 (A, B1, B2, D), 2007 (A), 2009, 2010 (A,B), 2011 ( D), 2012, 2013, 2014, 2015, 2016, 2017, 2018, 2019, 2020 (A,B), 2021 (B), 2023, 2025, 2032, ; Electrical Test Per MIL-STD-883 paragraph 4.5
VQC   
Micross STS (Hi-Reliability Microelectronics)
1804 McCarthy Blvd
Milpitas, CA 95035
United States
Mr. Paul Kamper
Phone: (408) 904-4230  
883: 1003 (A-E 600V, 100 nA), 1004, 1005 (A-F, Ta, Tc), 1008 (A-D), 1009 (A-D), 1010 (A-C), 1011(A-C), 1014 (A1, A2, C1), 1015 (A-F, Ta, Tc), 2001(A-E), 2002(A-G), 2003 (Test A-C), 2004(A, A1, B1, B2, D,E), 2007(A-C), 2009, 2010 (A, B), 2011 (D), 2012, 2013, 2014, 2015, 2016, 2017 (hybrids), 2019, 2020 (A,B), 2023, 2024, 2025, 2026, 2027, 2028, 2030, 2031, 2032, 2036 (A,B, I-K), 2038, 3015, 3023, Electrical Test per MIL-STD-883 paragraph 4.5, HAST Biased (JESD22-A110, Continous Power Only), HAST Unbiased (JESD22-A118)
202: 101, 103, 104, 105, 106, 107, 108, 112, 201, 204, 206, 208, 210, 211A, 212, 213, 214, 215, 301, 302, 303, 304, 305, 306, 307
750: 1001 (A-D), 1020, 1021, 1022, 1038, 1041, 1042 (A,B), 1051 (A, B, C, F, G), 1056 (A-D), 1071 (C, D), 2006, 2016, 2026, 2031 (A, B, I-K), 2036 (A, E), 2046, 2052, 2056, 2057, 2066, 2071, 2081, 2082, 3001, 3011, 3026, 3030, 3036, 3041, 3061, 3066, 3071, 3076, 3236, 3240, 3261, 3401, 3405, 3411, 3413, 3415, 4001, 4011, 4016, 4021, 4022, 4023 (A, B), 4051, 4056
VQC VQE  VQP
Microtech Laboratories
538 Haggard St. Suite 402
Plano, TX 75074
United States
Mr. John Olson
Phone: (972) 633-0007  
Fax: (972) 633-1533
883: 2018
VQC   
NTS Labs, LLC Chicago
1660 Wall St Ste 100
Mount Prospect, IL 60056
United States
Ms. Amanda Mai
Phone: (847) 934-5300  
202: 101, 103, 104, 105, 106, 107, 108, 111, 201, 204, 208, 210, 211, 213, 214, 215, 301, 302, 303, 304, 305, 306, 307, 310
1344: 1001, 1002, 1003, 1004, 1005, 1011, 1016, 1017, 2001, 2002, 2003, 2004, 2005, 2007, 2008, 2010, 2013, 2014, 2016, 2017, 2018, 2019, 3001, 3002, 3003, 3006, 3007
   VQP
Oneida Recherche Services
Les Taissounieres B2, 1681 route des Dolines
06560 Valbonne Sophia Antipolis,
France
Mr. Thomas Besson
Phone: 33492928889  
Fax: (334) 929-20515
883: 1014 (A1, A2, A5), 1018 (volume of gas at 1 atm: greater than 0.0003cc)
750: 1018 (volume of gas at 1 atm: greater than 0.0003cc), 1071 (H1, H2, H3)
VQC VQE VQH 
Oneida Research Services Inc.
8811 American Way, Suite 100
Englewood, CO 80112
United States
Mr. Daniel Rossiter
Phone: (315) 736-5480  
Fax: (866) 537-6764
IPC-TM-650: 2.6.7.2 Thermal Shock (MIL-PRF-31032/5 and /6 only), 2.6.27 Thermal Stress, Convection Reflow, Assembly Simulation
750: 1018 (volume of gas at 1 atm: greater than 0.0003cc), 1071 (A, B, G1, G2, H1, H2, H3)
883: 1014 (A1, A2, A5, B1, B2, B3, B1/B2), 1018 (volume of gas at 1 atm: greater than 0.0003cc)
VQC VQE VQH 
Oneida Research Services Inc.
8282 Halsey Rd
Whitesboro, NY 134923400
United States
Mr. Daniel Rossiter
Phone: (315) 736-5480  
Fax: (315) 736-9321
202: 209
883: 1014 (A1, A2, A5, B1, B2, B3, B1/B2), 1018 (volume of gas at 1 atm: greater than 0.0006cc), 2009, 2010 (A, B), 2011 (D), 2012 (film and digital), 2016, 2017 (H, K), 2018, 2019, 2020 (A, B), 2032 (H, K)
Misc: ASTM E 595
750: 1018 (volume of gas at 1 atm: greater than 0.0006cc), 1071 (A, B, G1, G2, H1, H2, H3), 2017 (A), 2037 (D), 2052 (A, B), 2066, 2069, 2071, 2072, 2073, 2075, 2076 (film and digital), 2077, 2102
VQC VQE VQH 
Oneida Research Services Inc. (PA)
4201 Pottsville Pike
Reading, PA 19605
United States
Mr. Angelo DePasquale
Phone: (315) 736-5480   Extension: 2218
883: 1003 (A-F), 1004, 1008 (A-D), 1009 (A-D), 1010 (A-D, F), 1011 (A-C), 2001 (A-F), 2002 (A-B), 2003 (Test A, B), 2004 (A, A1, B1, B2, E), 2007 (A), 2015, 2026 (I-II), 2036 (A, B, I-K), HAST Biased (JESD22-A110), HAST Unbiased (JESD22-A118)
VQC   
Pacific Testing Labs
24950 Avenue Tibbetts
Valencia, CA 91355
United States
Ms. Cathy Kingsbury
Phone: (661) 257-1437  
Fax: (661) 257-2411
Misc: ASTM D 150, ASTM D 635, ASTM D 1005, ASTM E 345, ASTM E 595, ASTM G 21, J-STD 003
PWB: Full Suitability
IPC-TM-650: 2.1.1, 2.1.5, 2.1.8, 2.1.9, 2.2.1, 2.2.2, 2.2.5, 2.2.6, 2.2.7, 2.3.4, 2.3.15, 2.3.25, 2.3.38, 2.3.39, 2.4.1, 2.4.1.1, 2.4.3, 2.4.3.1, 2.4.8, 2.4.15, 2.4.18.1, 2.4.21, 2.4.22, 2.4.28.1, 2.4.36, 2.4.41.2, 2.4.42.2, 2.5.5.7, 2.5.7, 2.6.1, 2.6.3, 2.6.3.5, 2.6.4, 2.6.5, 2.6.7, 2.6.7.2, 2.6.8, 2.6.10
Conformal Coating: Full suitability (MIL-I-46058)
202: 101, 104, 105, 106, 107, 108, 201, 204, 206, 208, 210, 211, 213, 301, 302, 303, 215, 301, 302, 303, 304, 305, 306, 307, 308, 309, 310, 311, 312
 VQE  
Pennsylvania State University RSEC
101 Breazeale Nuclear Reactor
University Park, PA 168022301
United States
Dr. Jeffrey A Geuther
Phone: (814) 863-2745  
883: 1017 (radiation source only)
VQC   
PhotoMetrics Inc
15801 Graham St.
Huntington Beach, CA 92649
United States
Mr. Paul Reidel
Phone: (714) 895-4465  
Fax: (714) 893-4682
883: 2018, Destructive SEM
750: 2077
VQC VQE  
Pikes Peak Test Labs
4750 Edison Ave.
Colorado Springs, CO 809154106
United States
Mr. Kamden Collins
Phone: (719) 596-0802   Extension: 1013
Fax: (719) 596-0824
883: 1004, 1005 (A-D), 1010 (A-C, F), 1011 (A-C), 1015 (A-D), 2015
VQC   
Precision Test Solutions
6120 Hanging Moss Rd.
Orlando, FL 328073701
United States
Ms. Tracy Wild
Phone: (407) 551-3732  
Fax: (407) 671-0664
883: 1004, 1009, 1010 (C), 1011 (C), 1014 (B1, B2), 2001, 2002, 2003, 2004 (B2), 2007 (A, B), 2011 (D), 2012, 2015, 2016, 2020 (A, B), 2024
202: 101, 103, 106, 107, 201, 204, 209, 212, 213, 214
750: 1021, 1032, 1041, 1051, 1056, 1071 (A, C, E, G2), 2006, 2016, 2017, 2036 (A, D1, D2, E, F), 2037, 2046, 2052 (A), 2056, 2076, 2077
MIL-DTL-22992: Shell-to-contact resistance grounding, Contact Resistance, Dielectric Withstanding Voltage, Thermal Shock (Temperature Cycling), Air Leakage, Contact Retention, Insert Retention, Insulation Resistance, Humidity, Durability, Salt Spray (corrosion), Shell-to-Shell Conductivity, Cable Pull-Out, Vibration, Drop (class L), Water Immersion, Heat Rise (class L), Arc Rupture (class L), Fluid Immersion, Tensile
 VQE VQH VQP
Product Testing Center-Electronic
3990 E. Broad St.
Columbus, OH 432131152
United States
Mr. Eric Kelly
Phone: (614) 692-9862  
Fax: (614) 693-6963
750: 1011, 1021, 1051, 1071, 2016, 2056, 3001, 3011, 3015, 3026, 3030, 3036, 3041, 3043, 3061, 3066, 3071, 3076, 3240, 3241, 3404, 3405, 3407, 3411, 3413, 3415, 3421, 4000, 4001, 4011, 4016, 4021, 4022, 4023, 4046, 4051, 4056, 4066, 4076, 4201, 4026, 4211, 4219, 4221, 4226
202: 78, 101, 103, 104, 106, 107, 112, 201, 204, 208, 213, 301, 302, 303, 305, 307
883: 3001, 3002, 3003, 3004, 3004, 3005, 3006, 3007, 3008, 3009, 3010, 3011, 3013, 3014, 3020, 3021, 3022, 4001, 4002, 4003, 4004, 4005, 4006, 4007
EIA-364: 2, 3, 5, 6, 9, 10, 11, 13, 17, 18, 20, 21, 23, 24, 26, 27, 28, 29, 30, 31, 32, 33, 35, 37, 46, 54, 58, 59, 69, 78, 83, 100, 101, 103, 105, 106, 108, 110
 VQE VQH VQP
Radiation Test Solutions
5030 Centennial Blvd.
Colorado Springs, CO 80919
United States
Mr. Daryl Istre
Phone: (719) 531-0800  
883: 1005 (A-F, air, Ta, Tc), 1014 (B1, B2, B1/B2, B3), 1015 (A-F, air, Ta, Tc), 1017, 1019 (A-E), 1020, 1021, 1023, Electrical Test per MIL-STD-883 paragraph 4.5 (25 degress C only)
750: 1017, 1019 (A-E), 1071 (A, B, G1 and G2), 2071, 3011 (A), 3036, 3041, 3061, 3066, 3071, 3076
VQC VQE VQH 
Radtest, Ltd.
D Wing, HQ Building Thomson AvenueThomson Avenue
Harwell, Oxfordshire OX11 0GD
United Kingdom
Mr. Richard Sharp
Phone: 44 (0) 1235 436620  
883: 1019 (A-E)
750: 1019 (A-C)
VQC VQE  
Raytheon, an RTX Business
2000 E El Segundo Blvd Bldg E1
El Segundo, CA 90245
United States
Mr. Willie Ho
Phone: (310) 647-2528  
883: 1015 (Ta, air), 1019 (A-D, ELDRS evaluation using Cobalt-60 gamma ray source and alanine dosimetry), Electrical Test per MIL-STD-883 paragraph 4.5
750: 1019 (A), 2017, 2026, 2036, 2037, 2052, 2066, 2068, 2071, 2073, 2074, 2075, 2076, 2077, 3001, 3011, 3026, 3036, 3041, 3061, 3066, 3071, 3076, 3401, 3403, 3404, 3405, 3407, 3411, 3413, 3415, 3421, 3423, 3474, 4011, 4016, 4021, 4022, 4051
 VQE VQH 
Raytheon, an RTX Business
2000 East El Segundo Blvd.
El Segundo, CA 90245
United States
Mr. Luigi L Aranda
Phone: (310) 647-9487  
883: 1014 (A1, A2, C1), 2003 (Test A), 2004 (B2), 2009, 2010 (A, B), 2011 (D), 2012, 2013, 2016, 2018, 2019, 2020 (A)
VQC   
Raytheon, an RTX Business
350 Lowell Street
Andover, MA 01810
United States
Mr. Stephen E Earley
Phone: (978) 470-6213  
883: 2003 (Test A), 2009, 2010 (A, B), 2011 (D), 2013, 2016, 2018, 2019, 2020 (A)
750: 2017, 2026, 2037, 2066, 2068, 2077
VQC VQE  
Raytheon, an RTX Business
50 Apple Hill Dr.
Tewksbury, MA 01876
United States
Mr. Stephen E Earley
Phone: (978) 470-6213  
750: 2076
883: 2012, 2018
VQC   
Raytheon, an RTX Business
2501 West University Drive
McKinney, TX 75071
United States
Mr. Jason L Wheeler
Phone: (972) 952-2581  
883: 2009, 2010 (A, B), 2012, 2013, 2016, 2018, 2019, 2020 (A)
750: 2017, 2052, 2066, 2068, 2076, 2077
VQC VQE  
Raytheon, an RTX Business
1151 East Hermans Road
Tucson, AZ 85756
United States
Ms. Jennifer L Dahar
Phone: (520) 545-8784  
883: 1014 (A1, A2, C1), 2009, 2010 (A, B), 2011 (D), 2012, 2013, 2016, 2018, 2019
750: 2017, 2037, 2066, 2071, 2072, 2073, 2075, 2076, 2077
VQC VQE  
Reliability Quality Engineering Inc.
2528 Qume Drive, Suite 9
San Jose, CA 95131-2102
United States
Mr. Paul Dhaliwal
Phone: (408) 655-9383  
883: 1005 (A-F), 1015 (A-F)
VQC   
Renesas Electronics America Inc. Corporation
1650 Robert J. Conlan Blvd. NE
Palm Bay, FL 32905
United States
Ms. Heather Cohn
Phone: (321) 456-6648  
750: 1019, 1020, 1042 (A, B), 1080, 3403, 3405, 3407, 3411, 3413, 3421, 3475, 4011
883: 1004, 1005 (A-E), 1009 (A-D), 1010 (A-F), 1011 (B, C), 1014 (A1, A2, B, C), 1015 (A-E), 1019 (A, D), 2001 (A-E), 2002 (B), 2003, 2004 (B1, B2, D), 2007 (A), 2009, 2010 (A, B), 2011 (C, D), 2012, 2013, 2014, 2015, 2016, 2018, 2019, 2020 (A, B), 2021, 2023, 2024, 2025, 2027, 3015, 3021, Electrical Test per MIL-STD- 883 paragraph 4.5
VQC VQE  
Resion LLC
7060 Havertys Way
Lakeland, FL 33805
United States
Ms. Ruby Arce
Phone: (516) 471-1520  
QTSL: Testing per AS6171 General Requirements and Slash sheets 2 (Methods A-E), 3, 4, and 5
VQC   
Retlif Testing Laboratories
795 Marconi Ave.
Ronkonkoma, NY 117797231
United States
Mr. Scott Poggi
Phone: (631) 737-1500  
461: CE101, CE102, CS101, CS114, CS115, CS116, RE101, RE102, RS101, RS103
810: 500, 501, 502, 503, 507, 509, 510, 513, 514, 516
202: 101, 103, 104, 105, 106, 107, 108, 109, 110, 201, 204, 206,207, 208, 210, 211,212, 213, 214, 215, 301
   VQP
Rink International LLC
1089 Nelson Creek Ln
Princeton, ID 83857
United States
Dr. Karl K Rink
Phone: (208) 874-2838  
883: 1014 (B1, B2, B1/B2, B3)
750: 1071 (A, B, G1, G2)
 VQE VQH 
Rochester Electronics Inc.
16 Malcolm Hoyt Dr.
Newburyport, MA 01950
United States
Mr. Steven Hirschfeld
Phone: (978) 270-0432  
JEDEC: Solderability J-STD-002 (A, A1, B, B1, S, S1), MSL J-STD-020, Acoustic Microscopy J-STD-035, Temp Cycle JESD22-A104, HAST Biased JESD22-A110, HAST Unbiased JESD22-A118, Pre-Cond Surface Mount JESD22-A113, Ball Shear JESD22-B117
883: 1004, 1005 (A-F), 1008 (A-H), 1009 (A-D), 1010 (A-F), 1011 (A-C), 1014 (A2, A4, C1), 1015 (A-F), 2001 (A-E), 2002 (A, B), 2003 (A, B), 2004 (B1, B2, D), 2007 (A), 2009, 2010 (A,B), 2011 (D), 2012, 2013, 2014, 2015, 2016, 2018, 2019, 2020 (A, B), 2021, 2023, 2024, 2025, 2027, 2028, 2036 (B), 2037, 5007, 5009, Electrical Test per MIL-STD-883 paragraph 4.5
VQC   
SERMA TECHNOLOGIES
14, rue Galile
PESSAC, 33615
France
Mr. Kvin BOURSIER
Phone: 33 (0)5 57 26 08 82  
883: 2030
VQC   
SMT Corporation
14 High Bridge Road
Sandy Hook, CT 06482
United States
Ms. Judith Johnson
Phone: (203) 270-4723  
Fax: (203) 270-4794
883: 1005 (A-E), 1010 (A-E), 1014 (A1, A2, A5), 1015 (A-E), 2001 (A-E), 2011 (D), 2019, 2020 (A, B), Electrical Test per MIL-STD-883 paragraph 4.5
QTSL: Testing per AS6171 General Requirements and Slash sheets 2 (Methods A-E), 3, 4, 5, and 7 (Limited Electrical Test per QTSL-5961/5962 3.1.3 Troom)
750: room temperature only (3001, 3011, 3026, 3030, 3036, 3041, 3061, 3066, 3071, 3076, 3086, 3092, 3101, 3401, 3403, 3404, 3405, 3407, 3411, 3413, 3415, 3421, 4000, 4001, 4011, 4016, 4021, 4022, 4023, 4026, 4031, 4041, 4046, 4051, 4056, 4061, 4076, 4201, 4206, 4211, 4219, 4221, 4306)
VQC   
SST Components LLC
780 Boston Rd
Billerica, MA 01821
United States
Mr. Mark McNulla
Phone: (978) 670-7300  
750: 1016, 1020, 1022, 1026, 1027, 1031, 1032, 1033, 1037, 1038 (A, B), 1039 (A, B), 1040, 1048, 1051 (A-D, F, G), 1056 (A-D), 1071 (H1, H2, CH1, CH2), 1081, 2006 (A-E), 2017 (A), 2026 (A, B), 2031 (A-D), 2036 (D1, D2, E, F), 2037 (D), 2052 (A), 2066, 2068, 2071, 2072, 2073, 2074, 2075, 2078, 3001, 3011, 3036, 3041, 3051, 3061, 3066, 3071, 3076, 3100, 3101, 3131, 3181, 3201, 3206, 3211, 3216, 3236, 3240, 3246, 3251, 3306, 3401, 3403, 3405, 3407, 3411, 3413, 3421, 3423, 4001, 4011, 4016, 4021, 4022, 4023, 4051, 4071, 4081, 4201, 4206, 4211, 4219, 4221, 4226
 VQE  
Semipack Services Inc.
1230 W Southern Ave #150
Tempe, AZ 85282
United States
Ms. Kim Bloyd
Phone: (321) 327-5930  
883: 2003 (Test A), 2037
VQC   
Six Sigma
905 Montague Expressway
Milpitas, CA 95035
United States
Mr. Russell Winslow
Phone: (408) 956-0100  
Fax: (408) 956-0199
883: 1014 (A1, A2, C1), 2003, 2009, 2011, 2015, 2038
VQC   
Spectrum Control Ltd. Test House
Test House, Fenner Rd. South Denes, Great Yarmouth
Norfolk, England NR30 3PX
United Kingdom
Mr. Dennis Bridge
Phone: 44 (0) 1493 743149  
883: 1003 (600V 100nA and A-F), 1004, 1005 (A-D, Ta, Tc), 1009, 1010 (A-C), 1011 (A-C), 2001 (A-E, Y1 axis), 2002 (A-G), 2003, 2004 (A1, B1, B2, D), 2007 (A-C), 2015, 2026 (A-K, I, II), 2036 (B)
  VQH VQP
Spirit Electronics
11202 N 24th Ave
Phoenix, AZ 85029
United States
Ms. Marti McCurdy
Phone: (480) 998-1533  
883: 1005 (A-D), 1008 (A-D), 1010 (A-E), 1015 (A-D), 2003 (Test A- C), 2009, 2011, 2012, 2013, 2018, 2019, 2020 (A, B), 2030, HAST Biased (JESD22-A110), HAST Unbiased (JESD22-A118)
VQC   
Stanford Technologies
57 Poplar St., P.O. Box 2100-D
Glenbrook, CT 06906
United States
Mr. Charles Cullari
Phone: (203) 348-4080  
1344: 1001, 1002, 1003, 1004, 1005, 1006, 2001, 2002, 2003, 2004, 2005, 2006, 2007, 2008, 2009, 2010, 2011, 2012, 2013, 2014, 2015, 2016, 2017, 2018, 3001, 3002, 3003, 3004, 3006, 3007
202: 101, 103, 104, 105, 106, 107, 108, 109, 110, 111, 112, 201, 204, 206, 207, 208, 210, 211, 213, 214, 215, 301, 302, 303, 304, 306, 307, 310, 311, 312
Misc: MIL-PRF-8805: Mechanical Endurance, Overload Cycling, Low Temperatrue Operation, Resistance to Soldering Heat, Strength of Mounting Bushing, Electrical Endurance
   VQP
Tektronix Service Solutions
7 Sterling Road
North Billerica, MA 01862
United States
Ms. Krystal Montero
Phone: (602) 395-5904  
883: 1003 (A-E 600 V, 100 nA), 1004, 1009 (A-D), 1010 (A, B, C), 1011 (A, B, C), 2001 (A-E, 30,000 gs, Y1 axis), 2002 (A-G), 2007 (A, B, C), 2015, 2026 (I, II, (A-K))
202: 101, 103, 104, 105, 106, 107, 108, 109, 201, 204, 212, 213, 214, 215, 301, 302, 303, 310
750: 1001, 1016, 1021, 1022, 1041, 1046, 1051, 1056, 2006, 2016, 2046, 2056, 2071
 VQE VQH VQP
Tektronix Service Solutions
1133 Rte. 23 N.
Wayne, NJ 07470
United States
Ms. Krystal Montero
Phone: (602) 395-5904  
810: 500, 503, 507, 509, 510, 513, 514, 516
202: 101, 103, 105, 106, 107, 108, 110, 201, 202, 203, 204, 205, 206, 207, 212, 213, 214, 301, 302, 310
   VQP
Teledyne e2v HiRel Electronics
765 Sycamore Drive
Milpitas, CA 95035
United States
Mr. Jonathan Thao
Phone: (408) 585-7130  
883: 1004, 1005 (A-D), 1009 (A, B), 1010 (B, C), 1011 (B, C), 1014 (A1, C1), 1015 (A-D), 2001 (A, B, D, E), 2002 (A, B), 2003, 2004 (B1, B2, D), 2007 (A), 2015, 2016, 2020 (A, B), 2024, 2025
VQC   
Trialon Corporation
1477 Walli Strasse Blvd
Burton, MI 48509
United States
Mr. Ron Dashkevicz
Phone: (810) 341-7937  
810: 501, 503 and Cold Environment Drop Test for M87819
202: 101, 103, and 201
   VQP
Trio-Tech International (VQC) Pte., Ltd.
327 Chalongkrung Road
Bangkok,
Thailand
Mr. Foo Chai
Phone: 65 62540255  
883: 1005 (A-E, 125C, Ta, air), 1015 (A-E, 125C, Ta, air)
VQC   
Trio-Tech International Pte., Ltd.
1004 Toa Payoh North #07-01/07
, 318995
Singapore
Mr. Foo Chai
Phone: 65 62540255  
883: 1005 (A-D, 125C, Ta, air), 1015 (A-E, 125C, Ta, air)
  VQH 
U.S. Army White Sands Missile Range
ATTN: SVAD
White Sands Missile Range, NM 880025158
United States
Ms. Jaclyn M Grelle
Phone: (575) 678-3186  
Fax: (575) 678-3999
883: 1017, 1019 (A-E and ELDRS), 1020, 1021, 1023
VQC   
University of Massachusetts-Lowell
1 University Ave
Lowell, MA 01854
United States
Mr. Leo Bobek
Phone: (978) 934-3365  
750: 1017 (radiation source only), 1019 (A, C; radiation source only)
883: 1017 (radiation source only), 1019 (A, C, D; radiation source only)
 VQE VQH 
VPT Components
9 Hampshire Street
Lawrence, MA 01840
United States
Mr. Toufiq Tayoubi
Phone: (978) 655-8893  
Fax: (978) 683-3264
883: 1003 (A-F), 1004, 1005 (A-D, F), 1008 (A-D), 1009 (A-D), 1010 (A-F), 1011 (A-C), 1014 (A1, A2, A4, A5,B1, B2, C1, D), 1015 (A-D, F), 2001 (A-E), 2002 (A-C), 2003 (A-D), 2004 (A, A1, B1, B2, D, E), 2007 (A-C), 2009, 2010 (A, B), 2011 (D, F), 2012, 2013, 2014, 2015, 2016, 2017, 2019, 2020 (A, B), 2023, 2025, 2032, 2036 (A, B), 2037, 2038, 3015, Electrical Test per MIL-STD-883 Paragraph 4.5
750: 1016, 1020, 1021, 1022, 1026, 1027, 1031, 1032, 1033 (A, B), 1037, 1038 (A, B), 1039 (A, B), 1040 (A, B), 1041, 1042, 1048, 1051 (A, F, G), 1054, 1055, 1056 (A, B, D), 1057 (B), 1071 (A, B, E, G1), 1081, 2005, 2006, 2016, 2017 (A), 2026, 2031 (A, B), 2036 (A, E), 2037 (D), 2038, 2052 (A), 2056, 2066, 2068, 2071, 2072, 2073, 2074, 2075, 2076, 2078, 2101, 3001, 3011, 3026, 3036, 3041, 3051, 3053 (B, C), 3061, 3066, 3071, 3076, 3100, 3101, 3131, 3161, 3181, 3201, 3206, 3211, 3216, 3236, 3240, 3246, 3251 (A, B), 3301, 3306, 3401, 3403, 3405, 3407, 3411, 3413, 3421, 3423, 3470, 3471, 3472, 3473, 3474, 3475, 3476, 4001, 4011, 4016, 4021, 4022, 4023 (A, B), 4026, 4031 (A, B), 4051, 4065, 4066 (A1, A2, B), 4071, 4081, 4201, 4206, 4211, 4219, 4221, 4223, 4224, 4226, 4231
VQC VQE  
VPT Radiation Laboratory and Test Services (VPT Rad)
101 Brick Kiln Rd, Suite 2, Unit 2
Chelmsford, MA 01824
United States
Mr. Thomas Regan
Phone: (978) 340-3442  
883: 1017, 1019 (A, C, D)
750: 1017, 1019 (A, C), 1080, 3001, 3011, 3026, 3036, 3041, 3061, 3066, 3071, 3076, 3401, 3403, 3404, 3405, 3407, 3411, 3413, 3415, 3421, 3423, 4011, 4016, 4021
 VQE VQH 
Valley Labs
3529 Old Conejo Rd., Ste. 112
Newbury Park, CA 91320
United States
Ms. Judy Milin
Phone: (805) 499-3613  
202: 107, 215, 301, 302
PWB: Full Suitability
 VQE  
Vertical Laboratories
1805 Flower Street
Glendale, CA 91201
United States
Mr. Kane Liang
Phone: (818) 858-1974  
EIA-364: Altitude immersion with IR and DWV (03), Fluid Immersion (10), Dielectric withstanding voltage @ sea level and altitude (20), Insulation resistance @ ambient and elevated temperature (21), Low Level Contact Resistance (23), Maintenance aging (24), Salt spray dynamic (26), Shock standard and half wave (27), Vibration sine and random (28), Contact Retention (29), Humidity (31), Temperature cycling (32), Insert retention (35), Hydrostatic Perssure (39), Firewall (45), Magnetic permeability (54), Shell to shell conductivity (83), Altitude low temperature with IR and DWV (105), Coupling and uncoupling torque (114)
MIL-DTL-32139: 4.7.16 Low-signal Level Contact Resistance, 4.7.23 Marking Performance, Intermateability, 4.7.6 Connector Mating and Unmating Forces, 4.7.17 Fluid Immersion
MIL-STD-1678: Sections 2, 3
MIL-STD-901: Mechanical Shock
38999: Durability, Electrical engagement, External bending moment, Bayonet coupling pin strength, Post test examination, Gauge location, Accessory thread strength, Shell spring finger forces, Ice resistance, High temperature exposure, Electrolytic erosion
202: 204, 208, 215
TIA: 455-6, 455-4, 455-14, 455-21, 455-71
MIL-PRF-29504: Test Methods: 4.8.2 Insertion Loss, 4.8.4 Return Loss, 4.9.8 Terminus Retention Force, 4.9.9 Terminus Engagement and Separation Force, 4.9.10 Thermal Shock , 4.9.11 Terminus Insertion and Removal forces, 4.9.12 Fiber Pull Out Force, 4.9.13 Cable Pull Out force , 4.9.14 Mating Durability
MIL-PRF-28876: Test Methods: 4.7.4.1 Insert Retention Radial Strength, 4.7.4.2 Insert Retention Axial Strength, 4.7.4.6 Connector Coupling Engagement and Disengagement Torque, 4.7.5.3 Fiber Cable Seal Flex, 4.7.5.4 Twist, 4.5.24 Contact Pin Strength, 4.7.6.1 Thermal Shock, 4.7.6.2 Temperature/Humidity Cycling, 4.7.6.3 Temperature Cycling, 4.7.6.11 Flammability, 4.7.6.16 Water Pressure
   VQP
White Horse Laboratories
29260 Clemens Rd
Westlake, OH 44145
United States
Mr. Mark Rinehart
Phone: (216) 477-1292  
QTSL: Testing per AS6171 General Requirements and Slash sheets 2 (Methods A-E), 3, 4, 5, and 7 (Limited Electrical Test per QTSL-5961/5962 3.1.3 Troom)
VQC   
Winchester Testing Laboratory Inc.
423 Pleasant St.
Melrose, MA 021764519
United States
Mr. David Fariole
Phone: (781) 665-9409  
750: 2076
883: 2012
202: 209
VQC VQE  
Xytek Industries Inc.
19431 West Davidson
Detroit, MI 48223
United States
Mr. Blair Kergan
Phone: (313) 838-6961  
Fax: (313) 838-3960
202: 106, 201, 213, 214
 VQE  
iTest
1905 Tarob Court
Milpitas, CA 95035
United States
Ms. Champ Daravong
Phone: (408) 418-1493  
883: Fremont: 1005 (A-F), 1006, 1010 A-C, 1015 (A-F), HAST Biased (JESD22-A110), HAST Unbiased (JESD22-A118) Milpitas: Electrical Test per MIL-STD-883 paragraph 4.5
VQC